Solutions

Building

Building covers a wild range, including office buildings, skyscrapers, residences, hotels, restaurants, shopping malls, schools, etc. Non-stop power supply is needed to operate the computers, lightings, electric appliance, elevators in these places. Power generators usually act as standby power, standing by main power.

 

 

Requirements and Challenges

 

1.Working conditions

 

24 hours consecutive stable power output at rated power (10% overload for 1 hour permissible each 12 hours), in the following conditions.
Altitude height: 1000 meters and below.
Temperature: lower limit -15°C, up limit 40°C

 

2.Low noise

 

Quite power supply with lower noise effect on work.

 

3.Stable performance & high reliability

 

Average failure interval: not less than 1000 hours
Voltage regulation range: at 0% load between 95%-105% of rated voltage.

 

Power Solution

 

Superb power generators, with PLC-5220 control module and ATS, assures immediate power supply the same time the main is gone. The generators adopt low noise design, and helps supply power in a quiet environment.

 

Advantages

 

l Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain. l The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop. l ATS for option. For small KVA machine, the ATS is integral. l Low noise. The noise level of the small KVA machine (30kva below) is below 60dB(A)@7m. l Stable performance. Average failure interval is not less than 1000 hours. l Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas. For bulk order, custom design and development is provided.

Hospital

Hospitals have a more demanding power supply. The power for hospitals allows absolutely no interrup- tion and must be provided in a super silent way. to meet the demanding requirements, the power generators must have excellent performance, also AMF and ATS are required.

 

 

Requirements and Challenges

 

1.Working conditions

 

24 hours consecutive stable power output at rated power (10% overload for 1 hour permissible each 12 hours), in the following conditions.
Altitude height 1000 meters and below.
Temperature lower limit -15°C, upper limit 40°C

 

2.Low noise

 

The power supply should be super low so that the doctors can work in quiet, also the patients can have an undisturbed rest environment.

 

3.Necessarily protective equipments

 

The machine will automatically stops and give signals in the following cases: low oil pressure, high temperature, over speed, start failure. For auto start power generators with AMF function, ATS helps realize auto start and auto stop. When the main fails, power generator can start within 5 seconds (adjustable). The power generator can start of itself consecutively for three times. The switch from main load to generator load completes within 10 seconds and reaches rated power output in less than 12 seconds. When the mains power gets back, the generators will automatically stop within 300 seconds (adjustable) after the machine cools.

 

4.Stable performance & high reliability

 

Average failure interval: not less than 2000 hours
Voltage regulation range: at 0% load between 95%-105% of rated voltage.

 

Power Solution

 

Superb power generators, with PLC-5220 control module and ATS, assures immediate power supply the same time the main is gone. The generators adopt low noise design, and helps supply power in a quiet environment. The engines are compliant with European and US emission standards. The machine can be connected with computer with RS232 OR RS485/422 connector to realize remote control.

 

Advantages

 

l Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain. l The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop. l ATS for option. For small KVA machine, the ATS is integral. l Low noise. The noise level of the small KVA machine (30kva below) is below 60dB(A)@7m. l Stable performance. Average failure interval is not less than 2000 hours. l Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas. l For bulk order, custom design and development is provided.

Mning

Fengde power solution for mining ensures high efficiency of mining exploration and process. Usually power generators are used as prime power source for daily life, engineering in mining site.

 

 

Requirements and Challenges
 
1.Working conditions

 

Altitude height 3000 meters and below.
Temperature lower limit -15°C, upper limit 40°C

 

2.Stable performance & high reliability

 

Average failure interval not less than 2000 hours

 

3.Convenient refueling and protection

 

Lockable exterior refueling system Large fuel tank, supporting 12 hours to 24 hours operation

 

Power Solution

 

Power Link generators featured by stable performance, easy operation, convenient maintenance, low noise, and exterior refuel system meet special requirements of mining.

 

Advantages

 

Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain.
The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop.
ATS for option. For small KVA machine, the ATS is integral.
Low noise. The noise level of the small KVA machine (30kva below) is below 60dB(A)@7m.
Stable performance. Average failure interval is not less than 2000 hours.
Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas.
For bulk order, custom design and development is provided.

Banks

Banks own large numbers of advanced computers and other equipments, which can only be operated in a demanding room. The room environment has a strict requirement for the temperature, humidity, cleanness, noise, static electricity, electromagnetic interference.

 

 

Requirements and Challenges

 

1.Working condition

 

24 hours consecutive stable power output at rated power (10% overload for 1 hour permissible each 12 hours), in the following conditions. Altitude height 1000 meters and below.
Temperature lower limit -15°C, uper limit 40°C

 

2.Low noise and clean emission

 

The power supply should be super low to ensure the safety of data system; also the staff in banks can enjoy an undisturbed working environment.
Clean emission can ensure the cleanness of the computer room and keep the computer system and data system safe.

 

3.Necessarily protective equipments

 

The machine can automatically inspect the start battery voltage and give an alarm. The machine will automatically stop and give relevant signals in the following cases: high water temperature, low water temperature, low water level, overload, start failure. The machine will stop in the following cases: over speed, short circuit, phase lack, over voltage, voltage loss, low frequency. The machine will give alarm in the following cases: low oil pressure, high water temperature, low water level, over load, start failure, over speed, short circuit, phase lack, over voltage, voltage loss, low frequency, low voltage for start battery, low oil level and relay connection in the alarm system.
For auto start power generators with AMF function, ATS helps realize auto start and auto stop. When the main fails, power generator can start within 5 seconds (adjustable). The power generator can start of itself consecutively for three times. The switch from main load to generator load completes within 10 seconds and reaches rated power output in less than 12 seconds. When the mains power gets back, the generators will automatically stop within 300 seconds (adjustable) after the machine cools Equipped with UPS.

 

4.With brushless PMG AC generator, the machine have strong anti-interference

 

performance, and strong short circuit withstand (usually 3 times of rated current for 10 seconds) acceptance capability

 

5.Stable performance & high reliability

 

Average failure interval not less than 2000 hours Voltage regulation range at 0% load between 95%-105% of rated voltage. When the load is below 50% of rated load, no low frequency surges 1.5 times of rated current overload at rated voltage for 2 minutes is permissible. The control system has remote control function, which can monitor, collect, process, record and report relevant data from at local or remote place.

 

Power Solution

 

High quality power generators, equipped with PLC-5220, which has AMF function, ensure non-stop power supply in the banks. With help of ATS, the power load can immediately switch to generator load once the main fails. The generators can run reliably and quietly, with clean emission compliant with European and US relevant emission standards. The machine can be connected with computer with RS232 OR RS485/422 connector to realize remote control.

 

Advantages

 

Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain.
The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop. ATS for option. For small KVA machine, the ATS is integral.
Low noise. The noise level of the small KVA machine (30kva below) is below 60dB(A)@7m.
Stable performance. Average failure interval is not less than 2000 hours.
Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas.
For bulk order, custom design and development is provided.

Telecom

Power generators are mainly applied for telecoms stations in telecoms industry. Usually, generator sets 800KW are needed for provincial station, and generator sets 300KW to 400KW are needed for municipal station, as standby power. For town or county station, 120KW and below are needed, usually as prime power.

 

 

Requirements and Challenges
 
1.Automatic functions

 

Auto start and auto loading
After receiving the start directive, the machine will start up automatically, with 99% success ratio. A start circle containers three start attempts. The interval between two start attempts is 10 to 15 seconds.
After successful start up, when the oil pressure reaches set value, the machine will load automatically. The load time is usually 10 seconds.
After three times of startup failure, the machine will give alarm reporting, and give start directive to the other standby generator set, if there is any.
Auto stop
When receiving the stop directive, the machine will stop automatically. There are two types: normal stop and emergency stop. The normal stop is to stop the power (and then break the air switch or switch ATS to the main). The emergency stop is to cut the power and fuel supply immediately.
Auto protection
The machines have protection against low oil pressure, over voltage, over speed, overload, short circuit and lack of phase. For water-cooled machines, also high water temperature protection is provided and high cylinder temperature protection for air-cooled machines.

 

2.Remote Control

 

The machine provides remote control system, monitoring the real time operation parameters and state. When abnormality or serious faults occur, the machine will give alarms. Standard communication protocols can be provided.

 

3.Paralleling operation

 

It can be realized through ATS auto switch between the main and generator or between two generators . Also, two or more same model generators can be paralleled to ensure bigger capability. The stable state speed regulation ratio is between 2% and 5%. The stable state voltage regulation is within 5%.

 

4.Working conditions

 

Altitude height 3000 meters and below. Temperature lower limit -15°C, upper limit 40°C

 

5.Stable performance & high reliability

 

Average failure interval not less than 2000 hours

 

6.Convenient refueling and protection

 

Lockable exterior refueling system Large fuel tank, supporting 12 hours to 24 hours operation.

 

Power Solution

 

Superb power generators, with PLC-5220 control module and ATS, assures immediate power supply at the same time the main is gone.

 

Advantages

 

Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain.
The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop. ATS for option. For small KVA machine, the ATS is integral.
Low noise. The noise level of the small KVA machine (30kva below) is below 60dB(A)@7m.
Stable performance. Average failure interval is not less than 2000 hours.
Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas.
For bulk order, custom design and development is provided.

Oil Fields

Fengde power provides a complete set of power solutions for oil fields, supplying power for oil exploration, gas process, oil production facility construction, operation and maintenance. Usually power generators are used as prime power source for daily life, engineering in oil fields.

 

 

Requirements and Challenges
 
1.Paralleling operation

 

More same model generators can be paralleled to ensure bigger capability. The stable state speed regulation ratio is between 2% and 5%. The stable state voltage regulation is within 5%.

 

2.Working

 

conditions Altitude height 3000 meters and below.
Temperature lower limit -15°C, upper limit 40°C

 

3.Stable performance & high reliability

 

Average failure interval not less than 2000 hours

 

4.Convenient refueling and protection

 

Lockable exterior refueling system Large fuel tank, supporting 12 hours to 24 hours operation

 

Power Solution

 

Superb power generators, with PLC-5220 control module and ATS, assures immediate power supply the same time the main is gone.

 

Advantages

 

Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain.
The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop. ATS for option. For small KVA machine, the ATS is integral.
Low noise, clean power.
Stable performance. Average failure interval is not less than 2000 hours. Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas.
For bulk order, custom design and development is provided.

Train Stations

What will happen if power is gone in a railway station? The fire system, safety system, telecom system, signals system, and data system will collapse; the whole station will get in a mess and horror; tremendous economic loss will be caused.

 

 

Requirements and Challenges

 

1.Low noise

 

The power supply should be super low without distraction of the workers, and also the passengers can enjoy a quiet environment.

 

2.Necessarily protective equipments

 

The machine will automatically stop and give signals in the following cases: low oil pressure, high temperature, over speed, start failure. For auto start power generators with AMF function, ATS helps realize auto start and auto stop. When the mains fails, power generator can start within 5 seconds (adjustable). The power generator can start of itself consecutively for three times. The switch from main load to generator load completes within 10 seconds and reaches rated power output in less than 12 seconds. When the main power gets back, the generators will automatically stop within 300 seconds (adjustable) after the machine cools.

 

3.Stable performance & high reliability

 

Average failure interval not less than 2000 hours
Voltage regulation range at 0% load between 95%-105% of rated voltage.

 

Power Solution

 

Usually the power source for a railway station consists of the main power and standby generators. The standby power generators should have AMF function and be equipped with ATS to ensure immediate switch to generators once the main fails. The generators can run reliably and quietly. The machine can be connected with computer with RS232 OR RS485/422 connector to realize remote control.

 

Advantages

 

l Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain. l The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop. l ATS for option. For small KVA machine, the ATS is integral. l Low noise, low affect to environment. l Stable performance. Average failure interval is not less than 2000 hours. l Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas. l For bulk order, custom design and development is provided.

Power Plants

Fengde power provides a comprehensive power solution for power plants, ensuring continuous power supply in case the power plant stops delivering power.

 

 

Requirements and Challenges
 
1.Working conditions

 

Altitude height 3000 meters and below.
Temperature lower limit -15°C, upper limit 40°C

 

2.Stable performance & high reliability

 

Average failure interval not less than 2000 hours

 

Power Solution

 

High quality generator sets with AMF function and ATS ensure immediate switch from the main to power generators the minute at the main fails.
Power Link supplies powerful and reliable generating sets meeting requirements of power plants.

 

Advantages

 

Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain.
The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop.
ATS for option. For small KVA machine, the ATS is integral.
Low noise. The noise level of the small KVA machine (30kva below) is below 60dB(A)@7m.
Stable performance. Average failure interval is not less than 2000 hours.
Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas.
For bulk order, custom design and development is provided.

Military

Diesel power generators for military use are mainly used as prime power for outdoors, weapons and devices, telecommunication, and civil defense.

 

 

Requirements and Challenges

 

1.Working conditions

 

Altitude height 3000 meters and below.
Temperature lower limit -15°C, upper limit 40°C.

 

2.Stable performance & high reliability

 

Average failure interval not less than 2000 hours.

 

3.Convenient refueling and protection

 

Lockable exterior refueling system.
Large fuel tank, supporting 12 hours to 24 hours operation.

 

4.Size and custom development

 

The generating sets for military use usually have to be in compact size and easy to move.
Usually the generators sets are custom developed to meet special requirements, including color and specifications.

 

Power Solution

 

Power Link generators featured by stable performance, easy operation, convenient maintenance, low noise, and exterior refuel system meet special requirements of military application.

 

Advantages

 

Whole set product and turn-key solution help customer use the machine easily without much technical knowledge. The machine is easy to use and maintain.
The control system has AMF function, which can auto start or stop the machine. In emergency the machine will give an alarm and stop.
ATS for option. For small KVA machine, the ATS is integral.
Low noise. The noise level of the small KVA machine (30kva below) is below 60dB(A)@7m.
Stable performance. Average failure interval is not less than 2000 hours.
Compact size. Optional devices are provided for special requirements for stable operation in some freezing cold areas and burning hot areas.
For bulk order, custom design and development is provided.